Ada Conformity Assessment Authority      Home Conformity Assessment   Test Suite ARGAda Standard
 
Ada Reference ManualLegal Information
Contents   Index   References   Search   Previous   Next 

4.6 Type Conversions

1/3
Explicit type conversions, both value conversions and view conversions, are allowed between closely related types as defined below. This subclause also defines rules for value and view conversions to a particular subtype of a type, both explicit ones and those implicit in other constructs.

Syntax

2
type_conversion ::= 
    subtype_mark(expression)
  | subtype_mark(name)
3
The target subtype of a type_conversion is the subtype denoted by the subtype_mark. The operand of a type_conversion is the expression or name within the parentheses; its type is the operand type.
4/3
One type is convertible to a second type if a type_conversion with the first type as operand type and the second type as target type is legal according to the rules of this subclause. Two types are convertible if each is convertible to the other. 
5/2
A type_conversion whose operand is the name of an object is called a view conversion if both its target type and operand type are tagged, or if it appears in a call as an actual parameter of mode out or in out; other type_conversions are called value conversions.

Name Resolution Rules

6
The operand of a type_conversion is expected to be of any type. 
7
The operand of a view conversion is interpreted only as a name; the operand of a value conversion is interpreted as an expression.

Legality Rules

8/2
In a view conversion for an untagged type, the target type shall be convertible (back) to the operand type. 
Paragraphs 9 through 20 were reorganized and moved below. 
21/3
 If there is a type (other than a root numeric type) that is an ancestor of both the target type and the operand type, or both types are class-wide types, then at least one of the following rules shall apply: 
21.1/2
The target type shall be untagged; or
22
The operand type shall be covered by or descended from the target type; or 
23/2
The operand type shall be a class-wide type that covers the target type; or 
23.1/2
The operand and target types shall both be class-wide types and the specific type associated with at least one of them shall be an interface type. 
24/3
 If there is no type (other than a root numeric type) that is the ancestor of both the target type and the operand type, and they are not both class-wide types, one of the following rules shall apply: 
24.1/2
If the target type is a numeric type, then the operand type shall be a numeric type.
24.2/2
If the target type is an array type, then the operand type shall be an array type. Further:
24.3/2
The types shall have the same dimensionality;
24.4/2
Corresponding index types shall be convertible;
24.5/2
The component subtypes shall statically match;
24.6/2
If the component types are anonymous access types, then the accessibility level of the operand type shall not be statically deeper than that of the target type;
24.7/2
Neither the target type nor the operand type shall be limited; 
24.8/2
If the target type of a view conversion has aliased components, then so shall the operand type; and 
24.9/2
The operand type of a view conversion shall not have a tagged, private, or volatile subcomponent. 
24.10/2
If the target type is universal_access, then the operand type shall be an access type.
24.11/2
If the target type is a general access-to-object type, then the operand type shall be universal_access or an access-to-object type. Further, if the operand type is not universal_access:
24.12/2
If the target type is an access-to-variable type, then the operand type shall be an access-to-variable type; 
24.13/2
If the target designated type is tagged, then the operand designated type shall be convertible to the target designated type;
24.14/2
If the target designated type is not tagged, then the designated types shall be the same, and either:
24.15/2
the designated subtypes shall statically match; or
24.16/2
the designated type shall be discriminated in its full view and unconstrained in any partial view, and one of the designated subtypes shall be unconstrained;
24.17/4
The accessibility level of the operand type shall not be statically deeper than that of the target type, unless the target type is an anonymous access type of a stand-alone object. If the target type is that of such a stand-alone object, the accessibility level of the operand type shall not be statically deeper than that of the declaration of the stand-alone object. 
24.18/2
If the target type is a pool-specific access-to-object type, then the operand type shall be universal_access
24.19/2
If the target type is an access-to-subprogram type, then the operand type shall be universal_access or an access-to-subprogram type. Further, if the operand type is not universal_access:
24.20/3
The designated profiles shall be subtype conformant.
24.21/4
The accessibility level of the operand type shall not be statically deeper than that of the target type. If the operand type is declared within a generic body, the target type shall be declared within the generic body.
24.22/4
    In addition to the places where Legality Rules normally apply (see 12.3), these rules apply also in the private part of an instance of a generic unit. 

Static Semantics

25
A type_conversion that is a value conversion denotes the value that is the result of converting the value of the operand to the target subtype.
26/3
 A type_conversion that is a view conversion denotes a view of the object denoted by the operand. This view is a variable of the target type if the operand denotes a variable; otherwise, it is a constant of the target type.
27
The nominal subtype of a type_conversion is its target subtype. 

Dynamic Semantics

28
For the evaluation of a type_conversion that is a value conversion, the operand is evaluated, and then the value of the operand is converted to a corresponding value of the target type, if any. If there is no value of the target type that corresponds to the operand value, Constraint_Error is raised; this can only happen on conversion to a modular type, and only when the operand value is outside the base range of the modular type. Additional rules follow: 
29
Numeric Type Conversion 
30
If the target and the operand types are both integer types, then the result is the value of the target type that corresponds to the same mathematical integer as the operand.
31
If the target type is a decimal fixed point type, then the result is truncated (toward 0) if the value of the operand is not a multiple of the small of the target type.
32
If the target type is some other real type, then the result is within the accuracy of the target type (see G.2, “Numeric Performance Requirements”, for implementations that support the Numerics Annex). 
33
If the target type is an integer type and the operand type is real, the result is rounded to the nearest integer (away from zero if exactly halfway between two integers). 
34
Enumeration Type Conversion 
35
The result is the value of the target type with the same position number as that of the operand value. 
36
Array Type Conversion 
37
If the target subtype is a constrained array subtype, then a check is made that the length of each dimension of the value of the operand equals the length of the corresponding dimension of the target subtype. The bounds of the result are those of the target subtype.
38
If the target subtype is an unconstrained array subtype, then the bounds of the result are obtained by converting each bound of the value of the operand to the corresponding index type of the target type. For each nonnull index range, a check is made that the bounds of the range belong to the corresponding index subtype. 
39
In either array case, the value of each component of the result is that of the matching component of the operand value (see 4.5.2). 
39.1/2
If the component types of the array types are anonymous access types, then a check is made that the accessibility level of the operand type is not deeper than that of the target type.
40
Composite (Non-Array) Type Conversion 
41
The value of each nondiscriminant component of the result is that of the matching component of the operand value. 
42
The tag of the result is that of the operand. If the operand type is class-wide, a check is made that the tag of the operand identifies a (specific) type that is covered by or descended from the target type.
43
For each discriminant of the target type that corresponds to a discriminant of the operand type, its value is that of the corresponding discriminant of the operand value; if it corresponds to more than one discriminant of the operand type, a check is made that all these discriminants are equal in the operand value.
44
For each discriminant of the target type that corresponds to a discriminant that is specified by the derived_type_definition for some ancestor of the operand type (or if class-wide, some ancestor of the specific type identified by the tag of the operand), its value in the result is that specified by the derived_type_definition.
45
For each discriminant of the operand type that corresponds to a discriminant that is specified by the derived_type_definition for some ancestor of the target type, a check is made that in the operand value it equals the value specified for it.
46
For each discriminant of the result, a check is made that its value belongs to its subtype. 
47
Access Type Conversion 
48/3
For an access-to-object type, a check is made that the accessibility level of the operand type is not deeper than that of the target type, unless the target type is an anonymous access type of a stand-alone object. If the target type is that of such a stand-alone object, a check is made that the accessibility level of the operand type is not deeper than that of the declaration of the stand-alone object; then if the check succeeds, the accessibility level of the target type becomes that of the operand type.
49/2
If the operand value is null, the result of the conversion is the null value of the target type. 
50
If the operand value is not null, then the result designates the same object (or subprogram) as is designated by the operand value, but viewed as being of the target designated subtype (or profile); any checks associated with evaluating a conversion to the target designated subtype are performed. 
51/4
 After conversion of the value to the target type, if the target subtype is constrained, a check is performed that the value satisfies this constraint. If the target subtype excludes null, then a check is made that the value is not null. If predicate checks are enabled for the target subtype (see 3.2.4), a check is performed that the value satisfies the predicates of the target subtype.
52
For the evaluation of a view conversion, the operand name is evaluated, and a new view of the object denoted by the operand is created, whose type is the target type; if the target type is composite, checks are performed as above for a value conversion.
53
The properties of this new view are as follows: 
54/1
If the target type is composite, the bounds or discriminants (if any) of the view are as defined above for a value conversion; each nondiscriminant component of the view denotes the matching component of the operand object; the subtype of the view is constrained if either the target subtype or the operand object is constrained, or if the target subtype is indefinite, or if the operand type is a descendant of the target type and has discriminants that were not inherited from the target type;
55
If the target type is tagged, then an assignment to the view assigns to the corresponding part of the object denoted by the operand; otherwise, an assignment to the view assigns to the object, after converting the assigned value to the subtype of the object (which might raise Constraint_Error);
56/4
Reading the value of the view yields the result of converting the value of the operand object to the target subtype (which might raise Constraint_Error), except if the object is of an elementary type and the view conversion is passed as an out parameter; in this latter case, the value of the operand object may be used to initialize the formal parameter without checking against any constraint of the target subtype (as described more precisely in 6.4.1).
57/4
 If an Accessibility_Check fails, Program_Error is raised. If a predicate check fails, the effect is as defined in subclause 3.2.4, “Subtype Predicates”. Any other check associated with a conversion raises Constraint_Error if it fails.
58
Conversion to a type is the same as conversion to an unconstrained subtype of the type. 
58.1/4
   Evaluation of a value conversion of a composite type either creates a new anonymous object (similar to the object created by the evaluation of an aggregate or a function call) or yields a new view of the operand object without creating a new object:
58.2/4
If the target type is a by-reference type and there is a type that is an ancestor of both the target type and the operand type then no new object is created;
58.3/4
If the target type is an array type having aliased components and the operand type is an array type having unaliased components, then a new object is created;
58.4/4
Otherwise, it is unspecified whether a new object is created. 
58.5/4
   If a new object is created, then the initialization of that object is an assignment operation.
NOTES
59
20  In addition to explicit type_conversions, type conversions are performed implicitly in situations where the expected type and the actual type of a construct differ, as is permitted by the type resolution rules (see 8.6). For example, an integer literal is of the type universal_integer, and is implicitly converted when assigned to a target of some specific integer type. Similarly, an actual parameter of a specific tagged type is implicitly converted when the corresponding formal parameter is of a class-wide type.
60
Even when the expected and actual types are the same, implicit subtype conversions are performed to adjust the array bounds (if any) of an operand to match the desired target subtype, or to raise Constraint_Error if the (possibly adjusted) value does not satisfy the constraints of the target subtype.
61/2
21  A ramification of the overload resolution rules is that the operand of an (explicit) type_conversion cannot be an allocator, an aggregate, a string_literal, a character_literal, or an attribute_reference for an Access or Unchecked_Access attribute. Similarly, such an expression enclosed by parentheses is not allowed. A qualified_expression (see 4.7) can be used instead of such a type_conversion.
62
22  The constraint of the target subtype has no effect for a type_conversion of an elementary type passed as an out parameter. Hence, it is recommended that the first subtype be specified as the target to minimize confusion (a similar recommendation applies to renaming and generic formal in out objects). 

Examples

63
Examples of numeric type conversion: 
64
Real(2*J)      --  value is converted to floating point
Integer(1.6)   --  value is 2
Integer(-0.4)  --  value is 0
65
Example of conversion between derived types: 
66
type A_Form is new B_Form;
67
X : A_Form;
Y : B_Form;
68
X := A_Form(Y);
Y := B_Form(X);  --  the reverse conversion 
69
Examples of conversions between array types: 
70
type Sequence is array (Integer range <>) of Integer;
subtype Dozen is Sequence(1 .. 12);
Ledger : array(1 .. 100) of Integer;
71
Sequence(Ledger)            --  bounds are those of Ledger
Sequence(Ledger(31 .. 42))  --  bounds are 31 and 42
Dozen(Ledger(31 .. 42))     --  bounds are those of Dozen 

Contents   Index   References   Search   Previous   Next 
Ada-Europe Ada 2005 and 2012 Editions sponsored in part by Ada-Europe